← All articles

RPM alert escalation: designing who the alert reaches next

An alert firing is only half the design problem. Who sees it first, when it moves to someone else, and what happens if nobody built that handoff with the people who staff it - that is a workflow question, not a colour or layout one.

Alert fatigue and status-colour design (covered elsewhere on this site) are both about how a single alert looks on screen. Escalation is a different design problem: where the alert goes once it fires, who reviews it first, and under what condition it moves to someone else. Get the look right and the workflow wrong, and a correctly-flagged reading can still sit with the wrong person, or reach the right person with no clear next step.

One escalation model, tested at scale

Mayo Clinic's multisite remote patient monitoring program for ambulatory COVID-19 patients ran two intensity tiers. The low-intensity tier served patients with no severe-illness risk factors: they entered vital signs manually, twice a day, on their own device, and a nurse team at a 1:50 nurse-to-patient ratio reviewed alerts through the EHR inbox. The high-intensity tier served higher-risk patients: Mayo supplied a cellular tablet and Bluetooth sensors that captured vitals passively, and a nurse team at a 1:30 ratio worked from a prioritized web console. In both tiers, a centralized registered nurse reviewed every alert first, applied a standardized decision tree, and escalated to a physician or advanced practice provider when the protocol called for it; a patient who needed hospitalization could be admitted directly, bypassing the emergency department.

The two tiers did not just generate a different volume of alerts - they generated a different mix of what needed escalation. The high-intensity tier produced alerts on 19.6% of scheduled monitoring tasks against 3.2% for low-intensity, and 18.8% of its alerts required escalation to a physician or APP against 9.4% for low-intensity - roughly 3 escalations per high-intensity patient against 1.5 for low-intensity. The design implication is specific: a passively-sensed, higher-risk cohort does not just need more nurse capacity, it needs a higher share of that nurse's queue to end in escalation. A single fixed nurse-to-physician ratio, set for one patient population, will not hold for another.

What breaks when the people in the escalation path aren't the ones who designed it

A small post-discharge heart failure monitoring pilot shows the failure mode in detail, even though it enrolled only five patients. A wearable sensor and a study phone fed alerts to home health nurses, who were meant to escalate to heart failure nurses or nurse practitioners, who in turn would involve a physician. In practice, the heart failure nurses had not been part of designing the pathway: they did not know the patients, gave the home health nurses no feedback once a case was escalated to them, and contributed to low buy-in across the team. The home health nurses were also often unsure exactly who to contact, which the study fixed mid-pilot with a single shared pager for the whole heart failure team - one destination instead of a list of names to guess from.

A second problem in the same pilot shows that alert design and escalation design are not separable. One alert type, flagging rapid breathing, was consistently mistaken by the home health nurses for a patient's normal baseline, so it was not escalated even when it should have been. No amount of fixing who the alert goes to helps if the person receiving it cannot tell the alert apart from business as usual - the team's fix combined both: it treated that alert as a possible early warning sign and added a clinical-assessment step rather than routing on the alert alone.

Limits of the evidence The heart failure pilot had five patients, and its problems describe one team's early rollout, not a universal pattern. The Mayo program was built for a specific disease (COVID-19) and a specific moment in the pandemic, not a general-purpose telehealth escalation protocol. Neither source compares escalation designs head to head; they describe what one team built and what happened.

What this means for design teams

  • Design the escalation pathway with the people who will staff it, before launch - the heart failure pilot's core failure was designing around the second-tier nurses rather than with them.
  • Give every escalation one clear destination, not a list of names a nurse has to pick from - a single shared contact point was the fix that mattered most in that pilot.
  • Build a feedback loop back to whoever escalated a case - "I sent it up and heard nothing" was what broke buy-in, not the escalation criteria themselves.
  • Expect the nurse-to-physician split to shift with patient risk tier or monitoring intensity rather than holding one ratio for every cohort - Mayo's two tiers needed two different ratios and produced two different escalation rates.
  • Treat an alert that can be mistaken for a stable baseline as an escalation-path problem too, not only an alert-design one - fixing the threshold alone did not fix the handoff.

Further reading

  • Coffey JD, Christopherson LA, Glasgow AE, et al. Implementation of a multisite, interdisciplinary remote patient monitoring program for ambulatory management of patients with COVID-19 - npj Digital Medicine, 2021 - https://pmc.ncbi.nlm.nih.gov/articles/PMC8363637
  • Chi WN, Reamer C, Gordon R, et al. Continuous Remote Patient Monitoring: Evaluation of the Heart Failure Cascade Soft Launch - Applied Clinical Informatics, 2021 - https://pmc.ncbi.nlm.nih.gov/articles/PMC8716190
  • Alert fatigue / notification thresholds (this site, Showcase) - the alert-appearance problem this article's escalation-workflow problem sits alongside